GROADA-AC380V-50KW-R/RCD Wechselrichter Lastbank
The GROADA AC380V-50KW-R/RCD inverter test load bank is a high-performance testing device specifical...
| Modell | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Nennleistung | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Eingangsstrom | 0 bis 22A | 0 bis 45A | 0 bis 45A | 0 bis 90A | 0 bis 45A | 0 bis 300A | 0-450A | 0 bis 600A | 0-750A |
| Größe (Breite * Tiefe * Höhe mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Gewicht | 50 kg | 80 kg | 100 kg | 130kg | 200 kg | 300 kg | 350 kg | 450kg | 550kg |
| Eingangsspannung | AC220 / 230V | AC380 / 400V | |||||||
| Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden | |||||||||
| Minimale Belastung | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden | |||||||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | ||||||||
| Leistungsfaktor | PF = 0,6 ~ 1,0 | ||||||||
| Spitzenkoeffizient | 2 bis 3 | ||||||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | ||||||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | ||||||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | ||||||||
| Arbeitsstromversorgung | AC220V | AC220V / AC380V | |||||||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden) | ||||||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | ||||||||
| Kalte sichere Weise | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | ||||||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | ||||||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | ||||||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | ||||||||
| Relative Luftfeuchtigkeit | ≤95% RH | ||||||||
| Höhe | ≤ 2500 m | ||||||||
DieGROADA-AC220V-30KW-RCD Inverter Load Bank is a state-of-the-art testing device designed to simulate real-world operational conditions for inverter systems. With a power capacity of 30 kW and operating at 220V AC, this load bank is engineered to assess the performance, efficiency, and safety of inverters under various load scenarios. Its Residual Current Device (RCD) functionality ensures comprehensive testing, making it an indispensable tool for manufacturers, researchers, and maintenance professionals in the power electronics industry.
Hohe Leistungskapazität: Delivers up to 30 kW of load, suitable for testing large-scale inverter systems.
RCD Functionality: Equipped with RCD to simulate fault conditions and assess safety mechanisms.
Verstellbare Lasteinstellungen: Allows precise control over load levels to simulate different operational scenarios.
Benutzerfreundliche SchnittstelleMit einem intuitiven Bedienfeld für einfache Bedienung und Überwachung.
Robuste Konstruktion: Built with durable materials to withstand rigorous testing environments.
Sicherheitskonformität: Meets international safety standards to ensure secure operation.
Wechselrichterprüfung: Simulates real-world loads to evaluate inverter performance and efficiency.
RCD Testing: Assesses the functionality of residual current devices in protecting against electrical faults.
UPS-Systeme: Tests uninterruptible power supplies under varying load conditions.
Power Electronics Research: Facilitates research and development in power electronics by providing controlled testing environments.
Educational Purposes: Serves as a practical tool for training and academic research in electrical engineering.
NennleistungLeistung: 30 kW
Eingangsspannung: AC 220V
Frequenz: 50 Hz
Lasttyp: Resistive-Reactance (RCD)
Kühlmethode : Zwangsluftkühlung
Protection Level: IP65
Steuermodus: Manual with digital display
Dimensions: Compact design for easy integration into test setups
Gewicht: Approximately 150 kg
The GROADA-AC220V-30KW-RCD Inverter Load Bank adheres to international standards such as IEC 61010-1 for safety requirements and IEC 62040-1 for uninterruptible power systems. Its design ensures safe operation and reliable performance in various testing scenarios.
Equipped with advanced features like precise load control and real-time monitoring, this load bank allows for accurate simulation of operational conditions. It supports both steady-state and transient testing, providing valuable data for performance analysis and optimization.
DieGROADA-AC220V-30KW-RCD Inverter Load Bank is a versatile and reliable tool for testing inverters and power electronic components. Its robust design, compliance with international standards, and advanced features make it an essential asset for professionals in the field of power electronics.