GROADA-AC120V-5KW-RCD Lastbank Hersteller
The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinea...
| Modell | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V - 30KW-RCD | AC380V - 50KW-RCD | AC380V - 60KW-RCD | AC380V - 100KW-RCD | AC380V - 200KW-RCD |
| Nennleistung | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Eingangsstrom | 0 bis 22A | 0 bis 45A | 0 bis 45A | 0 bis 90A | 0 bis 45A | 0 bis 300A | 0-450A | 0 bis 600A | 0-750A |
| Größe (Breite * Tiefe * Höhe mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Gewicht | 50 kg | 80 kg | 100 kg | 130kg | 200 kg | 300 kg | 350 kg | 450kg | 550kg |
| Eingangsspannung | AC220 / 230V | AC380 / 400V | |||||||
| Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden | |||||||||
| Minimale Belastung | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden | |||||||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | ||||||||
| Leistungsfaktor | PF = 0,6 ~ 1,0 | ||||||||
| Spitzenkoeffizient | 2 bis 3 | ||||||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | ||||||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | ||||||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | ||||||||
| Arbeitsstromversorgung | AC220V | AC220V / AC380V | |||||||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden) | ||||||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | ||||||||
| Kalte sichere Weise | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | ||||||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | ||||||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | ||||||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | ||||||||
| Relative Luftfeuchtigkeit | ≤95% RH | ||||||||
| Höhe | ≤ 2500 m | ||||||||
DieGROADA AC380V 30KW RCD Load Bank is a state-of-the-art solution for testing and validating modern power systems. Designed to replicate real-world electrical conditions, it provides precise simulation of non-linear loads, enabling engineers to assess the performance, efficiency, and reliability of generators, UPS systems, inverters, and other critical power equipment.
Whether for industrial operations, data centers, or renewable energy installations, this load bank ensures your systems are robust, resilient, and ready for any electrical scenario.
| Eigenschaften | Spezifikation |
|---|---|
| Nennleistung | 30 kW (Resistive) / 30 kVA (Capacitive) |
| Spannung | AC 380V, 3-Phasen |
| Frequenz | 50/60 Hz |
| Leistungsfaktorbereich | 0.6 – 1.0 (adjustable) |
| Maximum Current | Up to 576A (3-phase) |
| Lasttyp | Resistive-Capacitive (RCD) |
| Safety Protections | Overcurrent, overvoltage, overtemperature, emergency stop |
Key Insight: The combination of resistive and capacitive elements allows this load bank to generate non-linear load profiles that closely mimic modern electronic equipment behavior, ensuring realistic testing conditions.
Modern electrical systems often encounter non-linear loads due to electronic devices like computers, servers, and inverters. The RCD load bank replicates these conditions, allowing engineers to evaluate power system performance, including voltage stability, current harmonics, and thermal response under real operating scenarios.
Diepower factor adjustment range (0.6–1.0) ensures that your equipment can be tested under a variety of load conditions, from capacitive-heavy to predominantly resistive loads. This flexibility is critical for validating UPS, generator, and inverter performance under diverse operational scenarios.
With the ability to handle up to 576A in three-phase configurations, this load bank is suitable for medium to high-capacity power systems. It allows full-load testing without overloading the equipment under test, ensuring reliability and operational safety.
Safety is paramount in load testing. The GROADA RCD Load Bank is equipped with:
Overcurrent protection to prevent excessive load damage
Overvoltage protection to safeguard connected equipment
Overtemperature protection for internal heating control
Emergency stop for immediate shutdown during unexpected situations
The digital display provides continuous monitoring of:
Spannung und Strom
Real-time power consumption
Power factor and load distribution
This ensures precise, data-driven testing with minimal operator error.
The GROADA AC380V 30KW RCD Load Bank is ideal across multiple sectors:
Data Centers: Test UPS and backup generators under realistic, fluctuating load conditions.
Telecommunications: Validate the reliability of inverters and backup power for mission-critical networks.
Industrial Manufacturing: Confirm generator and electrical system resilience in factories and production facilities.
Renewable Energy: Evaluate inverters and hybrid energy systems in solar and wind installations to ensure optimal performance.
This load bank aligns with industry standards and best practices, including:
IEEE 1547 – Interconnection and performance of distributed energy resources
IEEE 112.3 – Generator testing methods
ISO 8528 – Reciprocating internal combustion engine-driven generating sets
Compliance guarantees trustworthy, repeatable testing results for both local and international projects.
Enhanced Testing Accuracy: Realistic simulation of non-linear loads ensures precise system evaluation.
Wide Application Range: Suitable for data centers, industrial sites, telecom networks, and renewable energy projects.
Long-Term Reliability: High-quality components for consistent performance over time.
Operator Safety: Built-in protections and emergency stop mechanisms safeguard users and equipment.
Investing in the GROADA AC380V 30KW RCD Load Bank means preparing your power systems for real-world demands, minimizing downtime, and optimizing operational efficiency.