GROADA-AC380V-30KW-RCD Lastbank Hersteller

★★★★★
Hauptprodukte:
  • AC-Lastbank: R / RL / RLC / RCD
  • DC-Lastbank: DC5V - 2000V, 0A - 5000A


ModellAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V - 30KW-RCDAC380V - 50KW-RCDAC380V - 60KW-RCDAC380V - 100KW-RCDAC380V - 200KW-RCD
NennleistungR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Eingangsstrom0 bis 22A0 bis 45A0 bis 45A0 bis 90A0 bis 45A0 bis 300A0-450A0 bis 600A0-750A
Größe (Breite * Tiefe * Höhe mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Gewicht50 kg80 kg100 kg130kg200 kg300 kg350 kg450kg550kg
EingangsspannungAC220 / 230VAC380 / 400V
Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden
Minimale Belastung100W100W100W100W100W1KW1KW1KW1KW
Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden
Gesamtgenauigkeit3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden)
LeistungsfaktorPF = 0,6 ~ 1,0
Spitzenkoeffizient2 bis 3
SteuermodusLokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden)
FernschnittstelleRS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden)
SchutzfunktionNotstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen)
ArbeitsstromversorgungAC220VAC220V / AC380V
Genauigkeit der Anzeige0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden)
AnzeigeparameterSpannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden)
Kalte sichere WeiseSeitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden)
SchutzstufeIP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden)
ErscheinungsfarbeRAL7035 (andere Farben können entsprechend Anforderungen angepasst werden)
Arbeitstemperatur-10 ℃ ~ 55 ℃
Relative Luftfeuchtigkeit ≤95% RH
Höhe ≤ 2500 m


GROADA AC380V 30KW RCD Load Bank – Advanced Non-Linear Load Testing Solution

DieGROADA AC380V 30KW RCD Load Bank is a state-of-the-art solution for testing and validating modern power systems. Designed to replicate real-world electrical conditions, it provides precise simulation of non-linear loads, enabling engineers to assess the performance, efficiency, and reliability of generators, UPS systems, inverters, and other critical power equipment.

Whether for industrial operations, data centers, or renewable energy installations, this load bank ensures your systems are robust, resilient, and ready for any electrical scenario.


🔧 Product Specifications

EigenschaftenSpezifikation
Nennleistung30 kW (Resistive) / 30 kVA (Capacitive)
SpannungAC 380V, 3-Phasen
Frequenz50/60 Hz
Leistungsfaktorbereich0.6 – 1.0 (adjustable)
Maximum CurrentUp to 576A (3-phase)
LasttypResistive-Capacitive (RCD)
Safety ProtectionsOvercurrent, overvoltage, overtemperature, emergency stop

Key Insight: The combination of resistive and capacitive elements allows this load bank to generate non-linear load profiles that closely mimic modern electronic equipment behavior, ensuring realistic testing conditions.


⚙️ Core Features and Advantages

1. Accurate Non-Linear Load Simulation

Modern electrical systems often encounter non-linear loads due to electronic devices like computers, servers, and inverters. The RCD load bank replicates these conditions, allowing engineers to evaluate power system performance, including voltage stability, current harmonics, and thermal response under real operating scenarios.

2. Adjustable Power Factor for Comprehensive Testing

Diepower factor adjustment range (0.6–1.0) ensures that your equipment can be tested under a variety of load conditions, from capacitive-heavy to predominantly resistive loads. This flexibility is critical for validating UPS, generator, and inverter performance under diverse operational scenarios.

3. High Current Capacity for Industrial Applications

With the ability to handle up to 576A in three-phase configurations, this load bank is suitable for medium to high-capacity power systems. It allows full-load testing without overloading the equipment under test, ensuring reliability and operational safety.

4. Integrated Safety and Reliability Features

Safety is paramount in load testing. The GROADA RCD Load Bank is equipped with:

  • Overcurrent protection to prevent excessive load damage

  • Overvoltage protection to safeguard connected equipment

  • Overtemperature protection for internal heating control

  • Emergency stop for immediate shutdown during unexpected situations

5. User-Friendly Interface and Real-Time Monitoring

The digital display provides continuous monitoring of:

  • Spannung und Strom

  • Real-time power consumption

  • Power factor and load distribution

This ensures precise, data-driven testing with minimal operator error.


📈 Industry Applications

The GROADA AC380V 30KW RCD Load Bank is ideal across multiple sectors:

  • Data Centers: Test UPS and backup generators under realistic, fluctuating load conditions.

  • Telecommunications: Validate the reliability of inverters and backup power for mission-critical networks.

  • Industrial Manufacturing: Confirm generator and electrical system resilience in factories and production facilities.

  • Renewable Energy: Evaluate inverters and hybrid energy systems in solar and wind installations to ensure optimal performance.


🌐 Compliance with International Standards

This load bank aligns with industry standards and best practices, including:

  • IEEE 1547 – Interconnection and performance of distributed energy resources

  • IEEE 112.3 – Generator testing methods

  • ISO 8528 – Reciprocating internal combustion engine-driven generating sets

Compliance guarantees trustworthy, repeatable testing results for both local and international projects.


💡 Why Choose GROADA AC380V 30KW RCD Load Bank?

  1. Enhanced Testing Accuracy: Realistic simulation of non-linear loads ensures precise system evaluation.

  2. Wide Application Range: Suitable for data centers, industrial sites, telecom networks, and renewable energy projects.

  3. Long-Term Reliability: High-quality components for consistent performance over time.

  4. Operator Safety: Built-in protections and emergency stop mechanisms safeguard users and equipment.

Investing in the GROADA AC380V 30KW RCD Load Bank means preparing your power systems for real-world demands, minimizing downtime, and optimizing operational efficiency.