GROADA-AC346V-50KVA-RL resistive induktive Lastbank
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| Modell | AC220V-6KW-R | AC380V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Nennleistung | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Größe (Breite * Tiefe * Höhe mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Gewicht | 25 kg | 80 kg | 130kg | 180 kg | 250 kg | 550kg | 650kg | 1100kg |
| Eingangsstrom | 0 bis 30A | 0 bis 45A | 0 bis 90A | 0 bis 150A | 0 bis 300A | 0 bis 600A | 0-750A | 0-1500A |
| Minimale Belastung | 100W | 100W | 500W | 1KW | 1KW | 5KW | 10kw | 50 KW |
| Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden | ||||||||
| Eingangsspannung | AC220 / 230V | AC380 / 400V | ||||||
| Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden | ||||||||
| Leistung | PF = 1,0 | |||||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | |||||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | |||||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | |||||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | |||||||
| Arbeitsstromversorgung | AC220V | AC220V / 380V | AC380V | |||||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden | |||||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | |||||||
| Kalte sichere Weise | Vorwärts und außen | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | ||||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | |||||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | |||||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | |||||||
| Relative Luftfeuchtigkeit | ≤95% RH | |||||||
| Höhe | ≤ 2500 m | |||||||
Erleben Sie Präzision, Zuverlässigkeit und fortschrittliche Technik mit demGROADA AC220V-50KW-R Lastbankeine leistungsstarke elektrische Prüflösung zur Simulation realer Wechselstromlast. Diese Lastbank ist für Effizienz, Haltbarkeit und Sicherheit konzipiert und ist ideal für Fachleute in der Stromerzeugung, Rechenzentren, erneuerbaren Energien und kritischen Infrastrukturtests.
Hochleistungskapazität:Liefert eine robuste Leistung von 50 kW bei 220 V AC, die eine genaue Prüfung von Generatoren, UPS-Systemen und Wechselrichtern ermöglicht.
Luftgekühlte Effizienz:Ein fortschrittliches Kühlsystem sorgt für eine optimale Wärmeabfuhr für längere Betriebe ohne Überhitzung.
Intuitives digitales Bedienfeld: User-friendly interface allows precise load adjustment, real-time monitoring, and accurate test reporting.
Integrated Safety Mechanisms: Equipped with over-temperature, over-current, and short-circuit protection to safeguard both equipment and operators.
Compact & Portable Design: Lightweight construction facilitates easy transportation and on-site deployment, making it suitable for a wide range of environments.
| Parameter | Details |
|---|---|
| Nennleistung | 50 kW |
| Nennspannung | 220V Wechselstrom |
| Kühlmethode | Luftgekühlt |
| Control | Digital control panel with load regulation |
| Protection | Over-temperature, over-current, short-circuit |
| Application | Generator testing, UPS, inverter testing, data centers, renewable energy systems |
DieGROADA AC Load Bank AC220V-50KW-R is specifically designed for comprehensive AC load testing. Typical applications include:
Generator Commissioning & Maintenance: Evaluate generator output, capacity, and efficiency under full-load conditions.
Uninterruptible Power Supply (UPS) Testing: Ensure seamless performance and reliability in critical power systems.
Inverter & Renewable Energy Testing: Accurately simulate loads to verify the functionality of solar, wind, and hybrid energy systems.
Data Center Infrastructure Verification: Test the resilience of power distribution and backup systems to maintain uninterrupted operation.
Industrial & Commercial Power Validation: Reliable load simulation for factories, hospitals, and commercial buildings requiring precise power assessment.
The global load bank market is experiencing rapid growth due to the increasing demand for power reliability, expansion of data centers, and adoption of renewable energy technologies. Key trends include:
Technological Advancements: Digital monitoring, modular designs, and regenerative load bank systems are revolutionizing the market, improving efficiency and reducing operational costs.
Market Growth: Industry reports project a compound annual growth rate (CAGR) of approximately 4.5% from 2025 to 2032, with the market expected to reach over USD 400 million.
Demand Drivers: The rise of backup power solutions, rigorous safety standards, and the need for accurate load testing are fueling adoption across sectors.
Exceptional Reliability: Built for demanding testing scenarios to deliver consistent, precise results.
Energy-Efficient Operation: Optimized air-cooled system minimizes energy consumption while maintaining high performance.
Ease of Use: Digital interface and intuitive controls reduce operator training time and simplify test procedures.
Comprehensive Safety: Multiple protection mechanisms safeguard both the load bank and connected equipment.
Multi-Industry Versatility: Ideal for generators, UPS, inverters, data centers, and renewable energy projects.
With the GROADA AC220V-50KW-R, power system professionals gain a dependable and high-performance solution for load simulation and performance verification. Its combination of precision engineering, safety, and adaptability ensures that every test is accurate, every system is reliable, and every operation meets the highest standards of excellence.
Invest in GROADA Load Banks to achieve efficiency, reliability, and peace of mind in every power testing application.