GROADA-AC346V-50KVA-RL resistive induktive Lastbank
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| Modell | AC220V-6KW-R | AC380V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Nennleistung | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Größe (Breite * Tiefe * Höhe mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Gewicht | 25 kg | 80 kg | 130kg | 180 kg | 250 kg | 550kg | 650kg | 1100kg |
| Eingangsstrom | 0 bis 30A | 0 bis 45A | 0 bis 90A | 0 bis 150A | 0 bis 300A | 0 bis 600A | 0-750A | 0-1500A |
| Minimale Belastung | 100W | 100W | 500W | 1KW | 1KW | 5KW | 10kw | 50 KW |
| Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden | ||||||||
| Eingangsspannung | AC220 / 230V | AC380 / 400V | ||||||
| Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden | ||||||||
| Leistung | PF = 1,0 | |||||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | |||||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | |||||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | |||||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | |||||||
| Arbeitsstromversorgung | AC220V | AC220V / 380V | AC380V | |||||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden | |||||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | |||||||
| Kalte sichere Weise | Vorwärts und außen | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | ||||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | |||||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | |||||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | |||||||
| Relative Luftfeuchtigkeit | ≤95% RH | |||||||
| Höhe | ≤ 2500 m | |||||||
DieGROADA AC520V-40A-R is a premium resistive AC load bank meticulously engineered for precision testing, maintenance, and verification of AC power systems. Designed for industrial, commercial, and renewable energy applications, this load bank allows engineers and technicians to simulate real-world electrical loads safely and accurately. It ensures your power systems—including generators, UPS, and energy storage units—operate at peak efficiency under both normal and extreme conditions.
High-Voltage Capacity – Supports 520V AC, adaptable for a wide range of industrial power systems.
Substantial Load Handling – Up to 40A load ensures comprehensive testing scenarios.
Intelligent Digital Control – Equipped with a sophisticated control panel for precise load adjustments and monitoring.
Robust & Durable Construction – Crafted with premium components to withstand rigorous testing environments.
Erweiterte Sicherheitsschutz – Integrated over-temperature sensors, circuit breakers, and fail-safe mechanisms ensure safe operation.
Compact & Portable Design – Facilitates easy integration into labs, power plants, or on-site generator testing locations.
The GROADA AC520V-40A-R is indispensable in sectors where power reliability is critical:
Generator-Tests – Verifies generator capacity, efficiency, and endurance under simulated real-world loads.
UPS Systems Evaluation – Ensures uninterruptible power systems are fully operational and compliant with performance standards.
Data Centers & Critical Facilities – Validates electrical infrastructure reliability, minimizing downtime risk.
Renewable Energy Testing – Provides accurate load simulation for solar, wind, and hybrid energy installations.
Electrical Engineering Labs – Offers precise load testing for research, development, and quality assurance.
The global AC load bank industry is expanding rapidly, driven by:
Rising demand for resilient power infrastructure across industries.
Accelerated adoption of renewable energy and microgrid technologies.
Increasing regulatory standards for generator and UPS performance.
Insight: Engineers and facility managers prioritize reliable, safe, and precise load testing equipment to prevent downtime and costly system failures. The GROADA AC520V-40A-R meets these market needs with unmatched quality and precision.
Precision Testing: Ensures accurate simulation of AC loads for robust system evaluation.
Versatility: Suitable for industrial generators, UPS systems, renewable energy setups, and lab applications.
Durability: Built to endure frequent testing and harsh environmental conditions.
Global Compliance: Designed to meet international safety and operational standards.
Expert Support: Backed by GROADA’s dedicated service and technical expertise.
| Spezifikation | Details |
|---|---|
| Modell | AC520V-40A-R |
| Spannung | 520V AC |
| Maximum Current | 40A |
| Lasttyp | Widerstandsfähig |
| Steuerschnittstelle | Digital Panel with Real-Time Monitoring |
| Safety | Over-Temperature Protection, Circuit Breakers |
| Anwendungen | Generator Testing, UPS, Data Centers, Renewable Energy Systems |
With the GROADA AC520V-40A-R, experience precision, reliability, and efficiency in power system testing. Whether ensuring backup generator readiness or evaluating UPS and renewable energy systems, this load bank delivers the confidence and accuracy your operations demand.