GROADA-AC220V-20KW-RCD Nichtlineare Lastbank

★★★★★
Hauptprodukte:
  • AC-Lastbank: R / RL / RLC / RCD
  • DC-Lastbank: DC5V - 2000V, 0A - 5000A


ModellAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V-30KW-RCDAC380V-50KW-RCDAC380V-60KW-RCDAC380V-100KW-RCDAC380V-200KW-RCD
NennleistungR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Eingangsstrom0 bis 22A0 bis 45A0 bis 45A0 bis 90A0 bis 45A0 bis 300A0-450A0 bis 600A0-750A
Größe (Breite * Tiefe * Höhe mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Gewicht50 kg80 kg100 kg130kg200 kg300 kg350 kg450kg550kg
EingangsspannungAC220 / 230VAC380 / 400V
Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden
Minimale Belastung100W100W100W100W100W1KW1KW1KW1KW
Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden
Gesamtgenauigkeit3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden)
LeistungsfaktorPF = 0,6 ~ 1,0
Spitzenkoeffizient2 bis 3
SteuermodusLokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden)
FernschnittstelleRS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden)
SchutzfunktionNotstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen)
ArbeitsstromversorgungAC220VAC220V / AC380V
Genauigkeit der Anzeige0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden)
AnzeigeparameterSpannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden)
Kalte sichere WeiseSeitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden)
SchutzstufeIP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden)
ErscheinungsfarbeRAL7035 (andere Farben können entsprechend Anforderungen angepasst werden)
Arbeitstemperatur-10 ℃ ~ 55 ℃
Relative Luftfeuchtigkeit ≤95% RH
Höhe ≤ 2500 m



GROADA AC220V 20KW RCD Nichtlineare Lastbank – Präzisionslastprüfung für moderne Stromanlagen

Die Sicherstellung der Zuverlässigkeit und Effizienz von Stromanlagen erfordert Prüflösungen, die die realen Betriebsbedingungen genau nachbilden. DieGROADA AC220V 20KW RCD Nichtlineare Lastbankist auf diesen Bedarf ausgelegt und bietet eine fortschrittliche nichtlineare Lastsimulation für Generatoren, UPS-Systeme, Wechselrichter und andere kritische Stromausrüstungen. Diese Lastbank ist sowohl für industrielle als auch kommerzielle Anwendungen konzipiert und bietet eine präzise, sichere und zuverlässige Leistungsprüfung unter realistischen elektrischen Belastungen.


🌟 Hauptmerkmale

Hohe Leistungskapazität

Mit einer Nennleistung von20 kWDiese Lastbank bietet ausreichende Kapazität, um eine Vielzahl von Geräten zu testen, von kleinen Industriegeneratoren bis hin zu großen UPS-Systemen.

Spannungskompatibilität

Optimiert fürAC 220V systems, it is versatile enough for diverse applications across different industries, ensuring seamless integration into existing electrical setups.

Nonlinear Load Simulation

Unlike traditional resistive-only load banks, the RCD load bank combines resistive and capacitive elements, accurately replicating the nonlinear characteristics of modern electrical loads. This ensures testing reflects real operational conditions, particularly for electronic-heavy loads.

Verstellbarer Leistungsfaktor

Equipped with an adjustable power factor range from 0.7 to 1, the load bank allows users to simulate varying load conditions, enabling thorough evaluation of power sources under both light and heavy reactive loads.

Comprehensive Monitoring

The built-in LCD display provides real-time monitoring of key electrical parameters such as voltage, current, power, and power factor. This ensures operators have full visibility over testing conditions at all times.

Robust Safety Features

Protective systems for overcurrent, overvoltage, and thermal management safeguard both the load bank and the equipment under test, minimizing risk during rigorous testing operations.


⚙️ Technische Spezifikationen

ParameterSpezifikation
Nennleistung20 kW
Nominal VoltageAC 220V
LasttypResistive + Capacitive (Nonlinear)
Leistungsfaktorbereich0.7 – 1
DisplayLCD
SchutzmerkmaleOvercurrent, Overvoltage
KühlmethodeZwangsluft

🏭 Ideal Applications

The GROADA 20KW RCD Nonlinear Load Bank is ideal for a broad range of professional applications, including:

  • Generators – Ensures reliable performance under dynamic loads, preventing overload and downtime.

  • Uninterruptible Power Supplies (UPS) – Verifies the ability to support critical loads during power interruptions.

  • Inverters – Assesses performance in real-world scenarios with fluctuating and nonlinear loads.

  • Rechenzentren – Simulates operational loads to maintain uptime and system reliability.

  • Telecommunications Equipment – Confirms network stability under complex electrical conditions.

This versatility makes it an essential tool for testing, commissioning, and maintaining critical electrical systems.


✅ Advantages of Choosing GROADA Load Banks

  1. Realistic Load Testing – Accurately replicates nonlinear electrical loads for true-to-life testing scenarios.

  2. Comprehensive Monitoring – Provides precise, real-time data for informed decision-making.

  3. Safe and Reliable Operation – Advanced protection mechanisms ensure equipment safety during testing.

  4. Wide Application Scope – Suitable for industrial, commercial, and mission-critical power systems.

  5. Industry Standard Compliance – Meets global standards for load testing, guaranteeing accuracy and credibility.


🔧 Why Reliability Matters

Modern power systems are increasingly exposed to nonlinear and dynamic loads due to the proliferation of electronic devices and renewable energy sources. Traditional load testing methods often fail to replicate these conditions accurately, leading to overestimation of equipment capacity or premature failures. The GROADA AC220V 20KW RCD Load Bank bridges this gap, ensuring your generators, UPS systems, and inverters are fully prepared for real-world operational stresses.


⚡ In Summary

DieGROADA AC220V 20KW RCD Nichtlineare Lastbank is more than a testing device – it is a tool for safeguarding your power infrastructure. Its combination of nonlinear load simulation, adjustable power factor, real-time monitoring, and robust safety features makes it indispensable for industries where electrical reliability is critical. Whether for industrial generators, data centers, or telecommunication networks, this load bank ensures your systems perform optimally, every time.

Unser Produkt