GROADA-AC600V-25KW-RCD Wechselrichter Lastbank
The GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-worl...
| Modell | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V - 30KW-RCD | AC380V - 50KW-RCD | AC380V - 60KW-RCD | AC380V - 100KW-RCD | AC380V - 200KW-RCD |
| Nennleistung | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Eingangsstrom | 0 bis 22A | 0 bis 45A | 0 bis 45A | 0 bis 90A | 0 bis 45A | 0 bis 300A | 0-450A | 0 bis 600A | 0-750A |
| Größe (Breite * Tiefe * Höhe mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Gewicht | 50 kg | 80 kg | 100 kg | 130kg | 200 kg | 300 kg | 350 kg | 450kg | 550kg |
| Eingangsspannung | AC220 / 230V | AC380 / 400V | |||||||
| Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden | |||||||||
| Minimale Belastung | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden | |||||||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | ||||||||
| Leistungsfaktor | PF = 0,6 ~ 1,0 | ||||||||
| Spitzenkoeffizient | 2 bis 3 | ||||||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | ||||||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | ||||||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | ||||||||
| Arbeitsstromversorgung | AC220V | AC220V / AC380V | |||||||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden) | ||||||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | ||||||||
| Kalte sichere Weise | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | ||||||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | ||||||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | ||||||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | ||||||||
| Relative Luftfeuchtigkeit | ≤95% RH | ||||||||
| Höhe | ≤ 2500 m | ||||||||
In modern power infrastructure, precision in testing and validating source behavior under real load conditions is essential. The AC 120V 50 kVA RCD inverter load bank from GROADA is engineered to simulate real electrical loads for inverter, UPS, generator, and battery systems under safe and repeatable conditions.
Using resistive, reactive, or combined load simulation, inverter load banks help reveal latent performance or stability issues before they can impact operations. This device is particularly valuable for:
Commissioning new power systems or inverters
Routine maintenance of energy storage systems
Stress testing of backup generators and UPS
Ensuring system compliance with safety and regulatory standards
Here is a high-level breakdown of the features your visitors will care about — and that will help search engines understand the page’s relevance and depth:
Rated Output: 120 V AC, 50 kVA
RCD protection & safety: includes Residual Current Device to protect operator and equipment
Inverter-compatible operation: supports bidirectional or controlled load injection to mimic inverter behavior
Precise load control: multi-step or continuous control, with accurate current/voltage metering
Cooling & thermal management: forced air cooling with intelligent fan control to manage resistor element temperature
Monitoring & communication: local display and optional remote interface (e.g. via RS-485, Ethernet, or other protocol)
Modular & maintainable design: replaceable resistor modules, easy access panels
Protection & safety features: overcurrent, overtemperature, short circuit, emergency stop
By emphasizing these aspects, the page signals both to users and to Google that it contains useful, detailed product content rather than shallow marketing fluff.
To build trust and authority, it’s useful to situate this product into its broader technical and market context:
What is a load bank?
A load bank is a device that imposes an electrical load on a power source in a controlled manner, converting that energy (usually via resistors) to heat, often dissipated by forced-air or water cooling systems. This allows engineers to test generators, UPSs, inverters, or batteries under known, stable loads without relying on unpredictable real-world load behavior.
Why inverter-compatible load banks?
Traditional resistive load banks impose static loads; inverter load banks, however, can more closely mimic dynamic power conversion behaviors (e.g. voltage drop, harmonic response) and can be used in conjunction with power electronics. This is especially relevant in modern microgrids, renewable systems, and energy storage test benches.
Market trends & demand
The global load bank market is projected to grow at a compound annual growth rate (CAGR) of ~3.7% from 2025 to 2032, expanding from ~$300 million in 2025 to ~$387 million by 2032.
Drivers include increased deployment of data centers, renewable energy integration, stricter power reliability standards, and wider use of battery/inverter systems. Enercon+1
In Asia-Pacific, especially China and India, industrial expansion and power infrastructure upgrades are accelerating demand for load testing and commissioning equipment.
By referencing these data points (with citations), the page demonstrates that the product is relevant in a growing, technology-driven sector.
To further increase relevance and user trust, lay out concrete scenarios where your product adds value:
| Application | Benefit / Use Case |
|---|---|
| Generator commissioning & acceptance testing | Verify full-load performance, thermal stability, load transient response |
| UPS & battery system verification | Confirm DC–AC inverter behavior under load, simulate real consumption profiles |
| Renewable + storage systems | During debugging/integration, impose known loads on inverter systems to test control logic |
| Maintenance & preventive testing | Routinely exercise systems to avoid “wet stacking,” carbon build-up, or capacity derating |
| Data center & mission critical facilities | Validate that backup systems can seamlessly take over under full load |
Including real user scenarios helps Google and users see your page as practically useful, boosting engagement and dwell time (factors that support SEO).
To help engineers / purchasers make informed decisions, you can include guidance or best practices:
Sizing margin: Choose a load bank with at least 20% headroom above expected maximum load to ensure longevity and safety under transient stress.
Power factor and reactance: If users need to test non-unity power factor loads (e.g. inductive or capacitive), consider combining with reactive modules or using R / L / C combination load banks.
Cooling & ambient conditions: The design must account for ambient temperature, ventilation constraints, and altitude.
Measurement accuracy: Use high-precision voltage and current sensors, with calibration, to ensure valid test data.
Safety and compliance: Design must comply with relevant electrical safety standards (e.g. IEC, UL, local codes), use proper insulation, earthing, overcurrent protection, and safe operator interface.
Maintenance tips: Periodic inspection of resistor elements, fan filters, connection integrity, insulation resistance, and firmware upgrades (if remote control is supported).
By offering this level of detail, the page becomes more than a sales pitch — it’s a resource, strengthening EEAT.
To boost trust (the “T” in EEAT), you should include or anchor (in surrounding parts of the site) elements like:
Company credentials & history: e.g. years of experience in power test / electrical load equipment manufacturing
Certifications & standards compliance: ISO, CE, UL, or others
Case studies / project references: real projects where this unit or similar ones were deployed (data centers, utility projects, etc.)
Third-party validation / testimonials: quotes from users, labs, or certifications
After-sales support & warranty: spare parts, calibration service, technical support coverage
In the body you can include a brief paragraph like:
GROADA is a specialist in power test solutions, with X years of experience designing reliable load banks. All units are factory tested, and we provide global after-sales support, spare parts, and calibration service to assure your long-term operational reliability.
Conclude with a user-focused, persuasive call to action, e.g.:
For detailed specifications, drawings, or customized configurations of the 120 V 50 kVA RCD inverter load bank, please contact our technical team. Let us help tailor a load testing solution that fits your system needs — from initial sizing to full test commissioning and long-term support.